{"title":"Melatherm accessories","description":"\u003cp\u003eMELAG‘s in-house development, the exceptionally variable Flex system provides numerous loading combinations, thus enabling optimal utilization of the washing chamber. Using flex basket 6 as a basis, it is possible to stack the various flex baskets 1, 2 and 3, the flex basket specula or the insert rack for scissors \/ clamps or impression trays in max. two levels. The picture on the right shows the ear speculum attachment flex 2 stacked on flex basket 3 in combination with flex-basket 1 and the ear speculum attachment flex 1. Beyond this, we also provide countless further variations.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTo request a sample box of accessories \u003c\/span\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/www.autoclave.nz\/pages\/melatherm-samples?_pos=1\u0026amp;_sid=b3e4398ad\u0026amp;_ss=r\" target=\"_blank\" title=\"Washer disinfector samples\" rel=\"noopener noreferrer\" style=\"color: #2b00ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"basket-with-injection-rail","title":"Basis Basket with Injection Rail and central Cleanfinity filter","description":"\u003cp\u003eDepending on the purpose of use, MELAG offers four basis baskets: with injector rail (without filter), with basis basket and central filter and a\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e \u003c\/span\u003e\u003ca title=\"Melag Melatherm basis basket without injector rail\" href=\"https:\/\/www.steriliser.nz\/collections\/melatherm\/products\/basket-without-injection-rail\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003ebasis basket without an injector\u003c\/span\u003e rail\u003c\/a\u003e. The basis baskets with injector rail are equipped with a reusable filter or disposable fine filter\u003cspan style=\"color: #0000ff;\"\u003e\u003c\/span\u003e. The injector rail can be fitted with\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e \u003c\/span\u003e\u003ca rel=\"noopener\" title=\"Injection rail acessories\" href=\"https:\/\/www.autoclave.nz\/collections\/injection-rail\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e11 various\u003c\/span\u003e \u003c\/a\u003ehollow adapters or with adapters for Luer \/ Luer-Lock connectors.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis makes it especially suitable for the decontamination of hollow instruments with an inner diameter of 0.8 mm, such as contra angles, air polishing devices and ultrasonic tips . The integrated control display in the injector rail indicates if the filter is blocked and should be cleaned. The central filter is then cleaned with the included cleaning brush. The basis basket with injector rail and central filter provides space for insert racks and baskets via 6 flex segments on up to 2 levels (not suitable for ophthalmology).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTo find a guide on what set up of accessories is right for you take a look at the Melatherm \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" title=\"Melatherm packages to help guide on what you may need in your washer disinfector\" href=\"https:\/\/www.autoclave.nz\/collections\/melatherm-packages\" target=\"_blank\"\u003epackages\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" title=\"Cleanfinity central filter system for Melatherm 10 washer disinfector\" href=\"https:\/\/www.youtube.com\/watch?v=Yerzqzyi2Uo\" target=\"_blank\"\u003eClick here\u003c\/a\u003e\u003c\/span\u003e to watch a short video on the filter system.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eLength: 43cm x Width: 42cm x Height: 12cm\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\"\u003eclick here\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca style=\"color: #0000ff;\" href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\"\u003eclick here\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116152434697,"sku":"MEL-84610","price":2395.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/84610-base_basket-Cleanfinity.jpg?v=1548835541"},{"product_id":"basket-without-injection-rail","title":"Basket without Injection Rail","description":"\u003cp\u003eDepending on the purpose of use, MELAG offers four basis baskets: with \u003ca href=\"https:\/\/www.steriliser.nz\/collections\/melatherm\/products\/basket-with-injection-rail\" title=\"Melag Melatherm Basis basket with injector rail to wash hand pieces\" rel=\"noopener noreferrer\" target=\"_blank\"\u003einjector rail\u003c\/a\u003e (without filter), with basis basket and central filter and a basis basket without an injector rail.\u003c\/p\u003e\n\u003cp\u003eThe basis baskets with injector rail are equipped with 11 \u003ca href=\"https:\/\/www.steriliser.nz\/collections\/melatherm-accessories\/products\/injection-nozzles\" title=\"Melag Melatherm Injector Nozzle accessories injection rail\" rel=\"noopener noreferrer\" target=\"_blank\"\u003einjector nozzles\u003c\/a\u003e \/ \u003ca href=\"https:\/\/www.steriliser.nz\/collections\/melatherm-accessories\/products\/locking-screw\" title=\"Melag Melatherm locking screws for injection rail\" rel=\"noopener noreferrer\" target=\"_blank\"\u003elocking screws\u003c\/a\u003e or with 11 blind screws. The injector rail can be fitted with various of hollow adapters or with adapters for Luer \/ Luer-Lock connectors.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116159381513,"sku":"3MEL-00188","price":1390.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/00188_melatherm10_zubehor_basiskorb_ohne_injektorschiene_EXT.jpg?v=1506911698"},{"product_id":"insert-rack-for-5-trays-10-half-trays","title":"Insert rack for 5 Trays\/10 Half Trays","description":"\u003cp\u003eFor the acceptance of up to 5 trays or 10 half trays.\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116206796809,"sku":"MEL-ME80590","price":324.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80590.jpg?v=1525551233"},{"product_id":"instrument-basket-g","title":"Instrument Basket \u003eG\u003c","description":"\u003cp\u003eFor vertically standing instruments such as e.g. scissors, tweezers, clamps, probes,\u003cbr\u003emirrors and dental aspirator tips with a connection for 11mm or 16mm.\u003cbr\u003eCan be combined with the Needle tip plate\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116212662281,"sku":"MEL-00131","price":545.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/00131_melatherm10_zubehor_waschkorb_g_EXT.jpg?v=1506928397"},{"product_id":"instrument-basket-compact","title":"Instrument Basket \u003eCompact\u003c","description":"\u003cp\u003eFor vertically standing instruments such as e.g. tweezers, probes, mirrors,\u003cbr\u003enasal specula and dental aspirator tips with a connection for 11mm or 16mm.\u003cbr\u003eCan be combined with the Needle tip plate\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116214169609,"sku":"3MEL-00195","price":435.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/00195_melatherm10_zubehor_instrumentenkorb_kompakt_EXT.jpg?v=1506928275"},{"product_id":"wash-tray-with-separation-inlay-and-penetration-protection","title":"Wash tray with separation inlay and penetration protection","description":"\u003cp\u003eFor the treatment of instrument sets or large quantities of individual instruments.\u003cbr\u003eCan be used in connection with the insert racks for perforated cartridges (\u003ca href=\"https:\/\/www.steriliser.nz\/products\/insert-rack-for-3-melastore-trays-wash-trays\" target=\"_blank\" title=\"Melag Melatherm insert rack for washer disinfector\" rel=\"noopener noreferrer\"\u003e#3\u003c\/a\u003e or \u003ca href=\"https:\/\/www.steriliser.nz\/products\/insert-rack-for-4-melastore-trays-wash-trays\" target=\"_blank\" title=\"Melag Melatherm insert rack for washer disinfector\" rel=\"noopener noreferrer\"\u003e#4\u003c\/a\u003e)\u003cbr\u003eExterior dimensions: Width: 17.5cm x Depth: 26.5cm x Height: 5cm\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116220362761,"sku":"3MEL-80185","price":720.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80185_melatherm10_zubehor_siebkassette_EXT.jpg?v=1506929016"},{"product_id":"protection-inlay-for-wash-tray","title":"Protection inlay for wash tray","description":"\u003cp\u003eSeparates instruments in the perforated cartridges so as to avoid spray shadow.\u003cbr\u003ePrevents protrusion through the perforated cartridge so as to protect instruments with sensitive points.\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cspan style=\"color: #0000ff;\"\u003eclick here\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116221509641,"sku":"3MEL-00189","price":130.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/00189_melatherm10_zubehor_schutzeinleger_siebkassette_EXT.jpg?v=1506930881"},{"product_id":"penetration-protection-for-wash-tray","title":"Penetration Protection for wash tray","description":"\u003cp\u003ePrevents the protrusion of pointed instruments through the wire gauze of the perforated cartridge.\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116224032777,"sku":"3MEL-00190","price":58.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/00190_melatherm10_zubehor_durchstechschutz_siebkassette_EXT.jpg?v=1506928913"},{"product_id":"separation-inlay-for-wash-tray","title":"Separation inlay for wash tray","description":"\u003cp\u003eSeparates instruments in the perforated cartridges so as to avoid spray shadow\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116226392073,"sku":"3MEL-00191","price":110.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/00191_melatherm10_zubehor_trenneinlage_siebkassette_EXT.jpg?v=1506929841"},{"product_id":"needle-tip-plate-for-instrument-basket","title":"Needle tip plate for instrument basket","description":"\u003cp\u003ePrevents sharp instruments from slipping through the basket meshing.\u003cbr\u003eCan be deployed in the \u003ca href=\"https:\/\/www.steriliser.nz\/products\/instrument-basket-standard\" target=\"_blank\" title=\"Melag Melatherm Wash basket washer disinfector\" rel=\"noopener noreferrer\"\u003einstrument basket \u003c\/a\u003e\u003cbr\u003eDimensions: Width: 17 cm x Depth: 3 cm x Height: 4.5 cm\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116227571721,"sku":"3MEL-00186","price":60.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/00186_melatherm10_zubehor_spitzenauflage_EXT.jpg?v=1506928785"},{"product_id":"small-parts-container","title":"Small Parts Container","description":"\u003cp\u003eFor the safe treatment of the smallest of instruments.\u003cbr\u003eThe small parts container can be placed in the flex basket or the instrument baskets.\u003cbr\u003eDimensions: Ø 7.6 cm x length: 18 cm\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116236976137,"sku":"3MEL-00133","price":55.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/00133_melatherm10_zubehor_kleinteilebehalter_EXT.jpg?v=1506929486"},{"product_id":"flex-basket-1","title":"Flex Basket 1","description":"\u003cp\u003eFor instruments lying flat e.g. scissors, tweezers, mirrors etc.\u003cbr\u003eStackable with flex baskets 1, \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" target=\"_blank\" title=\"Melag Melatherm washer disinfector Flex basket 2\" rel=\"noopener noreferrer\"\u003e2\u003c\/a\u003e, \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" target=\"_blank\" title=\"Melag Melatherm flex basket 3\" rel=\"noopener noreferrer\"\u003e3\u003c\/a\u003e and \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-6-with-tracerse-and-hose-conduit\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 6\" rel=\"noopener noreferrer\"\u003e6\u003c\/a\u003e.\u003cbr\u003eInterior dimensions: Width: 14.5 cm x Depth: 11 cm x Height: 6 cm\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116240515081,"sku":"3MEL-80010","price":375.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80010_melatherm10_zubehor_flexkorb_1_EXT.jpg?v=1506925255"},{"product_id":"flex-basket-2","title":"Flex Basket 2","description":"\u003cp\u003eFor instruments lying flat e.g. scissors, tweezers, mirrors, root elevators etc.\u003cbr\u003eStackable with flex baskets \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 1\" rel=\"noopener noreferrer\"\u003e1\u003c\/a\u003e,\u003cspan\u003e 2,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" target=\"_blank\" title=\"Melag Melatherm flex basket 3\" rel=\"noopener noreferrer\"\u003e3\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-6-with-tracerse-and-hose-conduit\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 6\" rel=\"noopener noreferrer\"\u003e6\u003c\/a\u003e.\u003cbr\u003eInterior dimensions: Width: 14.5 cm x Depth: 24 cm x Height: 6 cm\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116242612233,"sku":"3MEL-80020","price":445.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80020_Flexkorb2_print.jpg?v=1506925367"},{"product_id":"flex-basket-3","title":"Flex Basket 3","description":"\u003cp\u003eFor instruments lying flat e.g. scissors, tweezers, suction tubes etc.\u003cbr\u003eStackable with flex baskets\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 1\" rel=\"noopener noreferrer\"\u003e1\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" target=\"_blank\" title=\"Melag Melatherm washer disinfector Flex basket 2\" rel=\"noopener noreferrer\"\u003e2\u003c\/a\u003e,\u003c\/span\u003e\u003cspan\u003e 3 \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-6-with-tracerse-and-hose-conduit\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 6\" rel=\"noopener noreferrer\"\u003e6\u003c\/a\u003e.\u003cbr\u003eInterior dimensions: Width: 14.5 cm x Depth: 37.5 cm x Height: 6 cm\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116244709385,"sku":"3MEL-80030","price":525.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80030_melatherm10_zubehor_flexkorb_3_EXT.jpg?v=1506925496"},{"product_id":"flex-basket-6-with-tracerse-and-hose-conduit","title":"Flex Basket 6 with tracerse and hose conduit","description":"\u003cp\u003eFor long instruments lying flat e.g. scissors, tweezers, mirrors etc of a length up to 40 cm.\u003cbr\u003eAs a basis under the flex baskets\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" title=\"Melag Melatherm washer disinfector flex basket 1\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e1\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" title=\"Melag Melatherm washer disinfector Flex basket 2\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e2\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" title=\"Melag Melatherm flex basket 3\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e3\u003c\/a\u003e\u003cspan\u003e and\u003c\/span\u003e under the flex basket specula.\u003cbr\u003eInterior dimensions: Width: 34 cm x Depth: 38 cm x Height: 3 cm\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\" target=\"_blank\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\" target=\"_blank\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116246675465,"sku":"3MEL-80255","price":715.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80255_melatherm10_zubehor_flexkorb_6_traverse_schlauchdurchfuhrung_EXT.jpg?v=1506925621"},{"product_id":"injector-basket-flex-1","title":"Injector basket Flex 1","description":"\u003cp\u003eFor the reprocessing of up to 6 dental ultrasonic and scaler tips with torque wrench\u003cbr\u003eThe requisite filtration requires the \u003ca href=\"https:\/\/www.steriliser.nz\/products\/basket-with-injection-rail\" target=\"_blank\" title=\"Melag Melatherm washer disinfector basis basket with injection rail for hollowed instruments\" rel=\"noopener noreferrer\"\u003ebasis basket with injector rail\u003c\/a\u003e\u003cbr\u003eDelivery with hoses and 2 hose connectors with inner thread\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116249460745,"sku":"3MEL-80740","price":765.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80740.jpg?v=1525684371"},{"product_id":"supplementary-basket","title":"Flex supplementary basket (only for MELAtherm® 20)","description":"\u003cp\u003e\u003cspan\u003eWhether long, lying instruments or small parts containers, Comfort and Standard – the Flex Add-on Basket (internal dimensions BxHxT: 6,9 x 6 x 45,4 cm) creates additional space for specific requirements in instrument processing. \u003c\/span\u003e\u003cspan\u003eSuitable for use in the upper or lower rack of the MELAtherm 20, provided there is no injector rail module installed there. For maximum loading flexibility – as needed.\u003c\/span\u003e\u003cspan\u003eMore possibilities. More clarity. For a seamless workflow.\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116251721737,"sku":"MEL-80120","price":305.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ErgnzungskorbFlex-ME80120_877dfee2-49b5-4d81-a101-99179b5b94ea.avif?v=1789604186"},{"product_id":"flex-basket-specula","title":"Flex basket specula","description":"\u003cp\u003eFor gynaecological specula. Holds up to 8 sets Kristell \/ 16 Cusco \/ Semm specula.\u003cbr\u003e2 stackable on flex basket\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-6-with-tracerse-and-hose-conduit\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 6\" rel=\"noopener noreferrer\"\u003e6\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116256178185,"sku":"3MEL-80410","price":555.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80410_melatherm10_zubehor_flexkorb_spekula_EXT.jpg?v=1506925741"},{"product_id":"ear-speculum-attachment-flex-1-mesh-width-14mm","title":"Ear Speculum attachment flex 1, mesh width 14mm","description":"\u003cp\u003eFor up to 50 ear specula.\u003cbr\u003eFor setting on the flex baskets \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 1\" rel=\"noopener noreferrer\"\u003e1\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" target=\"_blank\" title=\"Melag Melatherm washer disinfector Flex basket 2\" rel=\"noopener noreferrer\"\u003e2\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" target=\"_blank\" title=\"Melag Melatherm flex basket 3\" rel=\"noopener noreferrer\"\u003e3\u003c\/a\u003e. Can also be used as a lid.\u003cbr\u003ePossible in any combination with the flex baskets 1, 2 and 3. Flex baskets can be\u003cbr\u003epartially filled with these or subject to comprehensive use (e.g. 3 on a flex basket 3).\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116257652745,"sku":"3MEL-80070","price":205.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80070_melatherm10_zubehor_ohrtrichter_flex_1_14_EXT.jpg?v=1506924741"},{"product_id":"ear-speculum-attachment-flex-1-mesh-width-20mm","title":"Ear speculum attachment flex 1, mesh width 20mm","description":"\u003cp\u003eFor up to 24 ear specula\u003cbr\u003eFor setting on the flex baskets \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" title=\"Melag Melatherm washer disinfector flex basket 1\" target=\"_blank\"\u003e1\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" title=\"Melag Melatherm washer disinfector Flex basket 2\" target=\"_blank\"\u003e2\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" title=\"Melag Melatherm flex basket 3\" target=\"_blank\"\u003e3\u003c\/a\u003e. Can also be used as a lid.\u003cbr\u003ePossible in any combination with the flex baskets \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" title=\"Melag Melatherm washer disinfector flex basket 1\" target=\"_blank\"\u003e1\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" title=\"Melag Melatherm washer disinfector Flex basket 2\" target=\"_blank\"\u003e2\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" title=\"Melag Melatherm flex basket 3\" target=\"_blank\"\u003e3\u003c\/a\u003e. Flex baskets can be\u003cbr\u003epartially filled with these or subject to comprehensive use (e.g. 2 on 1 flex basket 2).\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" style=\"color: #0000ff;\" target=\"_blank\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" style=\"color: #0000ff;\" target=\"_blank\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116259225609,"sku":"3MEL-80080","price":180.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80080_melatherm10_zubehor_ohrtrichter_flex_1_20_EXT.jpg?v=1506924829"},{"product_id":"ear-speculum-attachment-flex-2-mesh-width-20mm","title":"Ear speculum attachment flex 2, mesh width 20mm","description":"\u003cp\u003eFor up to 60 ear specula\u003cbr\u003eFor setting on the flex baskets \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 1\" rel=\"noopener noreferrer\"\u003e1\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" target=\"_blank\" title=\"Melag Melatherm washer disinfector Flex basket 2\" rel=\"noopener noreferrer\"\u003e2\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" target=\"_blank\" title=\"Melag Melatherm flex basket 3\" rel=\"noopener noreferrer\"\u003e3\u003c\/a\u003e. Can also be used as a lid.\u003cbr\u003ePossible in any combination with the flex baskets \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 1\" rel=\"noopener noreferrer\"\u003e1\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" target=\"_blank\" title=\"Melag Melatherm washer disinfector Flex basket 2\" rel=\"noopener noreferrer\"\u003e2\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" target=\"_blank\" title=\"Melag Melatherm flex basket 3\" rel=\"noopener noreferrer\"\u003e3\u003c\/a\u003e. Flex baskets can be\u003cbr\u003epartially filled with these or subject to comprehensive use (e.g. 1 on 2 flex baskets 1).\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116260700169,"sku":"3MEL-80090","price":230.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80090_melatherm10_zubehor_ohrtrichter_flex_2_20_EXT.jpg?v=1506924938"},{"product_id":"ear-speculum-attachment-flex-3-mesh-width-20mm","title":"Ear speculum attachment flex 3, mesh width 20mm","description":"\u003cp\u003eFor up to 96 ear specula.\u003cbr\u003eFor setting on the flex baskets \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 1\" rel=\"noopener noreferrer\"\u003e1\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" target=\"_blank\" title=\"Melag Melatherm washer disinfector Flex basket 2\" rel=\"noopener noreferrer\"\u003e2\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" target=\"_blank\" title=\"Melag Melatherm flex basket 3\" rel=\"noopener noreferrer\"\u003e3\u003c\/a\u003e. Can also be used as a lid.\u003cbr\u003ePossible in any combination with the flex baskets \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 1\" rel=\"noopener noreferrer\"\u003e1\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" target=\"_blank\" title=\"Melag Melatherm washer disinfector Flex basket 2\" rel=\"noopener noreferrer\"\u003e2\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" target=\"_blank\" title=\"Melag Melatherm flex basket 3\" rel=\"noopener noreferrer\"\u003e3\u003c\/a\u003e. Flex baskets can be\u003cbr\u003epartially filled with these or subject to comprehensive use (e.g. 1 on 3 flex baskets 1).\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116264370185,"sku":"3MEL-80100","price":285.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80100_melatherm10_zubehor_ohrtrichter_flex_3_20_EXT.jpg?v=1506925018"},{"product_id":"top-frame-for-flex-baskets-with-2-fixing-clamps","title":"Top frame for flex baskets, with 2 fixing clamps","description":"\u003cp\u003eFor self-retaining instruments e.g. nasal specula.\u003cbr\u003eUsable with flex baskets \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 1\" rel=\"noopener noreferrer\"\u003e1\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" target=\"_blank\" title=\"Melag Melatherm washer disinfector Flex basket 2\" rel=\"noopener noreferrer\"\u003e2\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" target=\"_blank\" title=\"Melag Melatherm flex basket 3\" rel=\"noopener noreferrer\"\u003e3\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116266139657,"sku":"MEL-80435","price":290.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80435.png?v=1506929292"},{"product_id":"fixing-clamp-for-top-frame","title":"Fixing clamp for top frame","description":"\u003cp\u003eAlready included in the scope of delivery of the\u003ca href=\"https:\/\/www.steriliser.nz\/products\/top-frame-for-flex-baskets-with-2-fixing-clamps\" target=\"_blank\" title=\"Fix clamp to top frame of flex basket for Melag Melatherm washer disinfector\" rel=\"noopener noreferrer\"\u003e top frame\u003c\/a\u003e for nose specula with the order no.\u003cbr\u003eAlso usable for all top frames for ear specula.\u003cbr\u003eFor fixing one top frame you need two pieces of the fixing clamp\u003c\/p\u003e\n\u003cp\u003eFor self-retaining instruments e.g. nasal specula.\u003cbr\u003eUsable with flex baskets 1, 2, and 3..\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116271710217,"sku":"MEL-80420","price":50.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80420_melatherm10_zubehor_halteklammer_flexaufsatz_EXT.jpg?v=1548837363"},{"product_id":"instrument-holder-for-flex-basket-60-pieces","title":"Instrument holder for flex basket, 60 pieces","description":"\u003cp\u003eFor insertion into the mesh of the flex baskets \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 1\" rel=\"noopener noreferrer\"\u003e1\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" target=\"_blank\" title=\"Melag Melatherm washer disinfector Flex basket 2\" rel=\"noopener noreferrer\"\u003e2\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" target=\"_blank\" title=\"Melag Melatherm flex basket 3\" rel=\"noopener noreferrer\"\u003e3\u003c\/a\u003e\u003cspan\u003e and \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-6-with-tracerse-and-hose-conduit\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 6\" rel=\"noopener noreferrer\"\u003e6\u003c\/a\u003e for fixing of instruments\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":116274757641,"sku":"MEL-80395","price":250.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80395.jpg?v=1506928513"},{"product_id":"insert-rack-for-impression-trays-scissors-and-clamps","title":"Insert rack for impression trays, scissors and clamps","description":"\u003cp\u003eFor up to 8 dental impression trays and also for scissors and clamps\u003cbr\u003eThe scissors and clamps are to be opened and hung from their ring grips (eyes).\u003cbr\u003eStackable with flex baskets \u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-1\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 1\" rel=\"noopener noreferrer\"\u003e1\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-2\" target=\"_blank\" title=\"Melag Melatherm washer disinfector Flex basket 2\" rel=\"noopener noreferrer\"\u003e2\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-3\" target=\"_blank\" title=\"Melag Melatherm flex basket 3\" rel=\"noopener noreferrer\"\u003e3\u003c\/a\u003e \u003cspan\u003eand \u003c\/span\u003e\u003ca href=\"https:\/\/www.steriliser.nz\/products\/flex-basket-6-with-tracerse-and-hose-conduit\" target=\"_blank\" title=\"Melag Melatherm washer disinfector flex basket 6\" rel=\"noopener noreferrer\"\u003e6\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eTo view a PDF on Melatherm accessories and instructions\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/zba_en_10dt_0_1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a compatibility chart of adapters for ultrasonic scaler tips\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0000ff;\"\u003e\u003ca href=\"https:\/\/www.melag.de\/sites\/default\/files\/compatibility_adaptors_tips.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"color: #0000ff;\"\u003eclick here\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"jstmedical","offers":[{"title":"Default Title","offer_id":8133786173528,"sku":"MEL-80110","price":390.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/80110_melatherm10_zubehor_einsatzgestell_abdruckloffel_EXT.jpg?v=1548836021"},{"product_id":"conversion-kit-injector-rail-with-cleanfinity-permanent-filter","title":"Conversion kit injector rail with Cleanfinity permanent filter","description":"\u003cp\u003eIf you have a Melatherm with the older style injection rail that required a filter for each hand piece adapter then this is the conversion kit to change it to the new central filter system.\u003c\/p\u003e\n\u003cp\u003eIncluded is the \u003ca href=\"https:\/\/www.autoclave.nz\/products\/central-filter-for-injector-rail\" target=\"_blank\" title=\"Cleanfinity central filter for injection rail on the Melag melatherm washer disinfector\" rel=\"noopener noreferrer\"\u003eCleanfinity\u003c\/a\u003e central filter which is one permanent filter through the middle of the injection rail making it easier and cheaper.\u003c\/p\u003e\n\u003cp\u003eThe Cleanfinity filter can be taken out and cleaned when required using the Cleaning Brush\u003c\/p\u003e\n\u003cp\u003eIf you have a basis basket without an injection rail and want to add a rail on then unfortunately this is not possible as the cap on the basis basket without is welded on. You will need to order a \u003ca href=\"https:\/\/www.autoclave.nz\/collections\/melatherm-accessories\/products\/basket-with-injection-rail\" target=\"_blank\" title=\"Basis baskit with injection rail and cleanfinity filter for Melag Melatherm washer disinfector\" rel=\"noopener noreferrer\"\u003ecomplete set\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=Yerzqzyi2Uo\" target=\"_blank\" title=\"Cleanfinity central filter system for Melatherm 10 washer disinfector\" rel=\"noopener noreferrer\"\u003eClick here\u003c\/a\u003e\u003cspan\u003e to watch a short video on the filter system\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":19581576839256,"sku":"MEL-84620","price":1350.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/products\/84620_injector-rail_cleaning-brush.jpg?v=1548835147"},{"product_id":"universal-flex-3","title":"Universal Flex 3","description":"\u003cp\u003e\u003cspan\u003eFor flexible mounting with freely selectable distances of up to: 12x \u003ca href=\"https:\/\/www.autoclave.nz\/collections\/packaging\/products\/melastore-tray-50\" title=\"Melastore tray 50 cassette\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eMELAstore Tray 50\u003c\/span\u003e\u003c\/a\u003e, 6x \u003ca href=\"https:\/\/www.autoclave.nz\/collections\/packaging\/products\/melastore-tray-100\" title=\"Melastore tray 100 cassette\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eMELAstore Tray 100\u003c\/span\u003e\u003c\/a\u003e, 5x \u003ca href=\"https:\/\/www.autoclave.nz\/collections\/packaging\/products\/melastore-tray-200\" title=\"Melastore tray 200 cassette\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eMELAstore Tray 200\u003c\/span\u003e\u003c\/a\u003e or 5x \u003ca href=\"https:\/\/www.autoclave.nz\/products\/wash-tray-with-separation-inlay-and-penetration-protection?_pos=1\u0026amp;_sid=01c6d814e\u0026amp;_ss=r\" title=\"Sieve insert tray\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003esieve cassette\u003c\/span\u003e\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":42837340618840,"sku":"80136","price":525.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80136_2.jpg?v=1745442090"},{"product_id":"universal-flex-1","title":"Universal Flex 1","description":"\u003cp\u003e\u003cspan\u003eFor flexible mounting with freely selectable distances of up to: 4x \u003ca rel=\"noopener\" title=\"Melastore tray 50 cassette\" href=\"https:\/\/www.autoclave.nz\/collections\/packaging\/products\/melastore-tray-50\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eMELAstore Tray 50\u003c\/span\u003e\u003c\/a\u003e, 2 x \u003ca rel=\"noopener\" title=\"Melastore tray 100 cassette\" href=\"https:\/\/www.autoclave.nz\/collections\/packaging\/products\/melastore-tray-100\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eMELAstore Tray 100\u003c\/span\u003e\u003c\/a\u003e, 1x \u003ca rel=\"noopener\" title=\"Melastore tray 200 cassette\" href=\"https:\/\/www.autoclave.nz\/collections\/packaging\/products\/melastore-tray-200\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eMELAstore Tray 200\u003c\/span\u003e\u003c\/a\u003e or 1x \u003ca rel=\"noopener\" title=\"Sieve insert tray\" href=\"https:\/\/www.autoclave.nz\/products\/wash-tray-with-separation-inlay-and-penetration-protection?_pos=1\u0026amp;_sid=01c6d814e\u0026amp;_ss=r\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003esieve cassette\u003c\/span\u003e\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":42837342552152,"sku":"80134","price":280.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80134.jpg?v=1745804537"},{"product_id":"universal-flex-2","title":"Universal Flex 2","description":"\u003cp\u003e\u003cspan\u003eFor flexible mounting with freely selectable distances of up to: 8x \u003ca rel=\"noopener\" title=\"Melastore tray 50 cassette\" href=\"https:\/\/www.autoclave.nz\/collections\/packaging\/products\/melastore-tray-50\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eMELAstore Tray 50\u003c\/span\u003e\u003c\/a\u003e, 4 x \u003ca rel=\"noopener\" title=\"Melastore tray 100 cassette\" href=\"https:\/\/www.autoclave.nz\/collections\/packaging\/products\/melastore-tray-100\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eMELAstore Tray 100\u003c\/span\u003e\u003c\/a\u003e, 3x \u003ca rel=\"noopener\" title=\"Melastore tray 200 cassette\" href=\"https:\/\/www.autoclave.nz\/collections\/packaging\/products\/melastore-tray-200\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003eMELAstore Tray 200\u003c\/span\u003e\u003c\/a\u003e or 3x \u003ca rel=\"noopener\" title=\"Sieve insert tray\" href=\"https:\/\/www.autoclave.nz\/products\/wash-tray-with-separation-inlay-and-penetration-protection?_pos=1\u0026amp;_sid=01c6d814e\u0026amp;_ss=r\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003esieve cassette\u003c\/span\u003e\u003c\/a\u003e.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":42843830779992,"sku":"80135","price":405.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80135.jpg?v=1745804656"},{"product_id":"flex-basket-8-only-for-melatherm-20","title":"Flex basket 8 - only for MELAtherm 20","description":"\u003cp\u003e\u003cspan\u003eSpecifically designed for the safe processing of long, flat-lying instruments up to 58 cm in length – such as needles or trocars – the Flex 8 (internal dimensions W x H x D: 34 x 3 x 49.8 cm) provides the ideal solution in the MELAtherm 20. At the same time, it serves as a robust base for combining with other Flex – Flex 1, 2, 3, 4 or the Flex Spekula – and thereby enables a modular, stackable loading concept. Long instruments? No problem. Stable, well thought-out and flexible to use.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831462457432,"sku":"ME80256","price":960.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80256.png?v=1789517493"},{"product_id":"flex-basket-4-only-for-melatherm-20","title":"Flex basket 4 - only for MELAtherm 20","description":"\u003cp\u003e\u003cspan\u003eThe Flex 4 (Internal dimensions W x H x D: 14,5 x 6 x 51 cm) is specifically designed for the MELAtherm 20 and offers optimal conditions for the horizontal storage of instruments such as scissors, forceps, mirrors or root elevators. Through its stackable construction, the basket can be placed space-saving onto another Flex 4 or 8 – for a flexible and expandable loading structure in the MELAtherm 20. Cleverly stacked. Safely prepared. Ready for any discipline.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831484706904,"sku":"ME20670","price":590.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME20670.png?v=1789518649"},{"product_id":"universal-flex-3-flat-bracket-melatherm-20","title":"Universal Flex 3 flat bracket - Melatherm 20","description":"\u003cp\u003e\u003cspan\u003eMore space, more structure: the flat Universal Flex 3 holder enables flexible storage in the upper basket of the MELAtherm 20 with individually selectable spacing. Ideal for holding up to 12 MELAstore Trays 33 or 6 MELAstore Trays 50 - for reprocessing processes with high throughput and clear organisation. If you need even more, simply add the additional holder (art. no. ME80233) - for a loading concept that adapts to everyday practice.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831519604824,"sku":"ME80236","price":495.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80236.png?v=1789520459"},{"product_id":"universal-flex-2-flat-bracket-melatherm-20","title":"Universal Flex 2 flat bracket- MELAtherm 20","description":"\u003cp\u003e\u003cspan\u003eFor those who want to accommodate more: the flat Universal Flex 2 holder provides flexible and organised storage in the top basket of the MELAtherm 20, with freely selectable spacing. Can be loaded with up to 8 MELAstore Trays 33 or 4 MELAstore Trays 50 – ideal for larger batches or standardised processing procedures, especially suitable in the top basket of the MELAtherm 20. With the additional holder (Art.-Nr. ME80233), the system can be expanded at any time – for maximum efficiency on two levels.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831531958360,"sku":"ME80235","price":380.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80235.png?v=1789520983"},{"product_id":"universal-flex-1-flat-bracket-melatherm-20","title":"Universal Flex 1 flat bracket - MELAtherm 20","description":"\u003cp\u003e\u003cspan\u003eSmall holder, big impact: The flat Universal Flex 1 holder allows for individual positioning of up to 4 MELAstore Trays 33 or 2 MELAstore Trays 50 – tailored to needs, especially suitable in the upper basket of the MELAtherm 20. Perfect for smaller batches, specific disciplines, or changing requirements in daily practice. With the additional holder (Art.-No. ME80233), the system can be expanded in no time – for more structure and efficiency in a compact space.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831561646168,"sku":"ME80234","price":270.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80234.png?v=1789521632"},{"product_id":"universal-flex-1-flat-bracket-melatherm-20-copy","title":"Universal Flex 4 bracket - MELAtherm 20","description":"\u003cp\u003e\u003cspan\u003eFull flexibility for full loading: Universal Flex 4, a new, customised bracket variant, is available to optimally utilise the extended potential of the enlarged base baskets in the MELAtherm 20. The bracket enables flexible installation with freely selectable distances - for maximum loading flexibility: up to 24 MELAstore Trays 33, 16 MELAstore Trays 50, 8 MELAstore Trays 100, 7 MELAstore Trays 200 or 7 sieve cassettes. Even more capacity? The system can be customised with the additional holder (art. no. ME80133) - for structured processes and maximum efficiency.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831568232536,"sku":"ME80137","price":640.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80137.png?v=1789521761"},{"product_id":"cleanfinity-pro-melatherm-20","title":"Cleanfinity Pro - MELAtherm 20","description":"\u003cp\u003e\u003cspan\u003eCleanfinity Pro introduces a new generation of filter technology: a self-cleaning central filter, integrated directly into the base of the wash chamber, which regenerates itself fully automatically during the programme run if required. Fewer steps. No running costs. Maximum safety when reprocessing hollow instruments. Cleanfinity Pro - an innovation for those who make no compromises.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831580520536,"sku":"ME84650","price":810.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME84650.png?v=1789521887"},{"product_id":"injector-rail-module-melatherm-20","title":"Injector rail module - MELAtherm 20","description":"\u003cp\u003e\u003cspan\u003eThe new injector rail module with 22 plastic blind screws can be easily integrated into the lower basket, enabling the reprocessing of hollow-body instruments in the MELAtherm 20. With up to 22 connections on two injector rails, the retrofit module provides optimal prerequisites for structured and safe cleaning and disinfection of hollow-body instruments – e.g., cannulas, handpieces and contra-angles, as well as many other delicate instruments. For even greater flexibility, capacity can be increased to up to 66 adaptable instruments by using additional dual- and triple-distributors. This ensures reliable and efficient interior cleaning even at high reprocessing volumes. An added level of safety, capacity and flexibility – perfectly aligned with the requirements of modern practices and clinics.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831596773464,"sku":"ME80840","price":1210.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80840.png?v=1789522045"},{"product_id":"melacontrol-wash-check-melatherm-20","title":"MELAcontrol Wash Check - MELAtherm 20","description":"\u003cp\u003e\u003cspan\u003eMake sure your instruments are cleaned to the highest quality at all times with the MELAcontrol Wash Check holder for the basis basket. This holder allows you to precisely check the cleaning performance of rigid and articulated instruments in the washing chamber of the MELAtherm washer-disinfector. The holder is attached to the basis basket for this purpose. After the cleaning cycle, the cleaning quality can be quickly and reliably assessed using an additional wash check indicator. With the MELAcontrol Wash Check holder for the basis basket, you can be sure that your instruments are always thoroughly cleaned. Rely on our wash check system for maximum hygiene and patient safety in your practice or clinic.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831610077272,"sku":"ME01073","price":55.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME01073.png?v=1789522194"},{"product_id":"din-sieve-trolley-only-for-melatherm-20","title":"DIN sieve trolley -  only for MELAtherm 20","description":"\u003cp\u003e\u003cspan\u003eMade for big tasks: With the loading trolley for up to 8 DIN trays, MELAG offers the ideal solution for outpatient operating centres and surgical clinics with high instrument throughput. Efficient utilisation of the interior space, stable design and maximum capacity - for smooth processes when every minute counts. Big thinking. Precisely realised. Ready for your daily operating theatre routine!\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831629344856,"sku":"ME80850","price":4100.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80850.png?v=1789522344"},{"product_id":"upper-basket-melatherm-20","title":"Upper basket - MELAtherm 20","description":"\u003cp\u003e\u003cspan\u003eWith a generous footprint of 52.9 x 47.3 cm, the upper basket in the MELAtherm 20 provides the perfect basis for customised loading concepts. Whether dental, gynaecological or ENT - the upper basket can be flexibly combined with adapters and inserts to meet the specific requirements of each speciality. Sophisticated efficiency - for safe, systematic instrument reprocessing.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831657558104,"sku":"ME80820","price":1190.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80820.png?v=1789522870"},{"product_id":"triple-distributor-without-filter-disc","title":"Triple distributor  without filter disc","description":"\u003cp\u003e\u003cspan\u003eFor the preparation of narrow-lumen hollow bodies, this three-way distributor is combined with the injection rail with a central filter. For up to three injection nozzles with a clamping spring, Luer \/ Luer-Lock adapter or tubing connections. The three-way distributor is suitable for the MELAtherm 10 and MELAtherm 20 series.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831667552344,"sku":"ME22611","price":270.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME22611.png?v=1789522779"},{"product_id":"lower-basket-melatherm-20","title":"Lower basket- MELAtherm 20","description":"\u003cp\u003e\u003cspan\u003eWhether dental, gynaecology, ENT, podiatry, veterinary medicine or other disciplines – the lower basket in the MELAtherm 20 offers the appropriate structure. Thanks to the base area of 8 Flex segments, which can be equipped on up to 2 levels with more than 90 stackable baskets and holders, you benefit from a true all-rounder for instrument processing. In addition, there is a free space on the right-hand side of the lower basket for the injector rail module. With this retrofit module and the appropriate adapters, even demanding hollow-bodied instruments can be reliably cleaned and disinfected from the inside at over 22 connections. Well thought-out down to the finest detail – ready for every requirement.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831690522712,"sku":"ME80830","price":1160.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80830.png?v=1789522975"},{"product_id":"silicone-closure-cap-white-10-pcs","title":"Silicone closure cap white  10 pcs","description":"\u003cp\u003e\u003cspan\u003eIf an adapter on the injector rail is not equipped with an instrument, it can quickly and easily be sealed with the silicone closure cap. The silicone closure cap white fits for adapters for ISO connection (INTRA coupling) (order no. 80610) and adapters for heads of KaVo contra angles (order no. 80630).\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831692488792,"sku":"ME89071","price":33.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME89071.png?v=1789522895"},{"product_id":"silicone-closure-cap-blue-10-pcs","title":"Silicone closure cap blue  10 pcs","description":"\u003cp\u003e\u003cspan\u003eIf an adapter on the injector rail is not equipped with an instrument, it can quickly and easily be sealed with the silicone closure cap. The silicone closure cap blue fits for connections for hoses with an inside Ø 6mm, external thread (order no. 80150), adapters for Sirona Classic (order no. 80620), adapters for W\u0026amp;H turbines (order no. 80640), adapters for Sirona Classic (order no. 80650) and adapters for KaVo turbines (MULTIflex connection) (order no. 80660).\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831697338456,"sku":"ME89061","price":33.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME89061.png?v=1789523004"},{"product_id":"stainless-steel-cover-plate-melatherm-20","title":"Stainless steel cover plate - MELAtherm 20","description":"\u003cp\u003e\u003cspan\u003eThe eye also cleans: If the MELAtherm 20 is not installed under a continuous worktop, the stainless steel cover plate provides a hygienic and aesthetically clean finish. It closes the gap between the appliance and the base cabinet, prevents dirt from entering and supports the consistent design of your work line - for a practice that not only works cleanly, but also looks it.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831718113368,"sku":"ME65320","price":550.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME65320.png?v=1789523097"},{"product_id":"silicone-closure-cap-green-10-pcs","title":"Silicone closure cap green  10 pcs","description":"\u003cp\u003e\u003cspan\u003eIf an adapter on the injector rail is not occupied by an instrument, it can be closed quickly and easily with the matching closure cap. The silicone closure cap green is compatible with e.g. the injector nozzle (order no. 73860) and adapters for tips (order no. 80750, 80751, 80752, 80756, 80760, 80790).\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831720013912,"sku":"ME89051","price":33.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME89051.png?v=1789523093"},{"product_id":"mediaguard-box-for-process-media","title":"MediaGuard Box for process media","description":"\u003cp\u003e\u003cspan\u003eThe separately available storage box ensures safe, clean and systematic storage of the MEtherm process media in the neighbouring base cabinet. Optionally tiltable with stand - for maximum ease of use. MediaGuard not only protects your process media, but also your practice furniture - and is therefore the clever upgrade for all those who prioritise tidiness.\u003c\/span\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831727747160,"sku":"ME80232","price":230.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80232.png?v=1789523215"},{"product_id":"melacontrol-wash-check","title":"MELAcontrol Wash Check","description":"\u003cdiv class=\"body cut-off cut-off-processed\"\u003e\n\u003cp\u003eWith the MELAcontrol Wash Check for your MELAtherm washer disinfector, you can always keep an eye on the cleaning performance. The 100 wash check indicators allow you to routinely monitor the cleaning results of instruments in the base basket or on the injector rail in accordance with DIN EN ISO 15883-5. It is very easy to use: Place one wash indicator in the separately available holder for the base basket or for the injector rail. After the cycle, a visual check of the indicator enables a quick assessment of the cleaning quality in the washer disinfector. With MELAcontrol Wash Check, you can ensure that your instruments are always thoroughly cleaned - for optimum hygiene and patient protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"pdf\"\u003e\u003c\/div\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831751700568,"sku":"ME01072","price":205.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME01072.png?v=1789523351"},{"product_id":"marking-discs-for-adapters-for-tips-18-pcs","title":"Marking discs for adapters for tips  18 pcs","description":"\u003cp\u003e\u003cspan\u003eThe marking discs are for the MELAtherm 10 and MELAtherm 20 series and serve to differentiate the adapters for ZEG tips. This helps prevent instruments from being accidentally screwed onto the wrong adapters and potentially damaging the threads. The set contains 6 green, 6 blue and 6 white marking discs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/Compatibility_chart.pdf?v=1789523242\" target=\"_blank\" title=\"Dental hand piece compatibility chart for adaptors\" rel=\"noopener\"\u003e\u003cspan\u003eCompatibility Chart\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"JST Medical Ltd","offers":[{"title":"Default Title","offer_id":44831753240664,"sku":null,"price":58.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/files\/ME80769.png?v=1789523296"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2182\/5857\/collections\/00184_melatherm10_zubehor_instrumentenkorb_stehende_instrumente_EXT.jpg?v=1525252878","url":"https:\/\/www.autoclave.nz\/collections\/melatherm-accessories.oembed?page=8","provider":"JST Medical Ltd","version":"1.0","type":"link"}