Melag Cliniclave 45 D
Melag Cliniclave 45 D
Melag Cliniclave 45 D
Melag Cliniclave 45 D
Melag Cliniclave 45 D
Melag Cliniclave 45 D

Melag Cliniclave 45 D

Regular price $89,000.00 Sale

Cliniclave 45 D

Double-door large steam steriliser for practice and clinic use

Fitted with an XXL colour-touch display on both sides, the double-door Cliniclave is loaded and started on the “impure side.” Unloading and approval are performed on the “pure side.” This large steam steriliser from the Cliniclave series brings the advantages of the single door 1 and 2 sterilisation unit steam sterilisers - record operating times, excellent drying results, integrated documentation and approval software, EN 1717 conformity and an individual loading concept. The tray mounts and possible loading configurations (of trays, containers and mesh instrument baskets) and the loading system can be used with all devices in the Cliniclave series.

Of especial note is the innovative installation and maintenance concept in comparison to other pass-through devices. Mounted on freely-moving casters, the Cliniclave 45 D can be slid into an opening in the wall and pulled out for any maintenance purposes. An especially adapted system of stainless steel covers enables the complete covering of the surrounding wall surface without the need for extra work.

With a loading capacity of up to 40 kg unwrapped and 35 kg wrapped instruments and up to 7 kg textiles, the Cliniclave 45 D enables a considerably greater performance than the majority of comparable large steam sterilisers. Used in connection with specially designed tray mounts, the cylindrical sterilisation chamber provides the best solution for all departments. Especially fast operating times, a high loading capacity and reliable sterilisation security represent the most important requirements for a large steam sterilizer in practice and clinic use. The quick operating times produced by the patented double-walled sterilization chamber of the Cliniclave 45 D make it the cornerstone of instrument decontamination. The Cliniclave 45 D represents the ideal large steam steriliser for clinics, practices and outpatient centres, requiring efficiency and planning for expansion.

Units can be networked along with the washer disinfector directly to your computer to download data logs with a free FTP software.

J.S.T. Medical also offers a  2 Year Warranty

 All Cliniclaves have a trolley set available to help with the loading and unloading 

For a PDF brochure with more information please click here

Units are supplied as left hand door hinge, they can be right hand on request but please note this will extend the delivery time frame as they are made to order at the factory.